Star Diopside has a specific gravity of 3.29 and a refractive index of 1.664–1.721, with a Mohs hardness of 5.0–6.0. It is biaxial +.

Physical & Optical Properties

RI Range1.664–1.721
SG Range3.27–3.36
SG Typical3.29
Hardness (Mohs)5–6
Crystal SystemMonoclinic
Optic CharacterDR Biaxial (+)
Birefringence0.030
Dispersion0.013
Fluorescence LWInert
Fluorescence SWInert
Chelsea FilterInert
PleochroismNone
ColorsBlack
SpeciesDiopside
VarietyBlack Star Diopside
Black

Measured with a polariscope, a refractometer, a hydrostatic balance, a Chelsea filter, a UV torch, a loupe, a darkfield loupe and a spectroscope — step-by-step for each.

Through the refractometer

Star Diopside varies 1.664 – 1.721 1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.80 REFRACTIVE INDEX DORotate the stone through a full 360°, reading both edges atevery 45°. SEETwo boundaries, 0.030 apart at their widest separation. Thepair drawn here is one specimen: this species is publishedat 1.664 – 1.721, and the two edges slide together anywhereacross it, between the dashed marks. MEANSThat gap IS the birefringence — and it is the stable part.Where the pair sits varies by 3 printed divisions from stoneto stone, so the gap identifies and the position onlynarrows. Take max minus min across the whole rotation; asingle position understates it. Computed from gems.json — edge positions are arithmetic, not drawn. RI increases upward; the field above the boundary is the dark one.

Drawn from the refractive index above, on a 1.40–1.81 scale. How to take this reading.

Through the polariscope

Star Diopside Blinks 4× per turn (DR) 0° 45° 90° 135° ROTATION BETWEEN CROSSED POLARS Star Diopside blinks light-dark four times in a full turn. That is doubly refractive. It does NOT tell you uniaxial from biaxial — that is the optic figure, which needs a conoscope. Computed from optic character and transparency in gems.json. A polariscope separates singly refractive, doubly refractive and aggregate — it does not show the optic sign.

Drawn from the optic character and transparency above. A polariscope separates singly refractive, doubly refractive and aggregate; the optic sign needs a conoscope. How to take this reading.

Specific gravity, and what it rules out

Star Diopside SG 3.27–3.36 WHERE IT SITS, AND WHAT ELSE IS THERE 1.0 2.0 3.0 4.0 5.0 SPECIFIC GRAVITY 9 other species in the table overlap this range, so a reading here narrows the field to 10 rather than naming the stone. Combine it with a refractive index to separate what is left. Computed from the specific-gravity range in gems.json. Hydrostatic weighing — the bench method this site recommends; heavy liquids are toxic and regulated. Faint ticks are the other species in the table.

Drawn from the specific-gravity range above, against every other species in the table. How to take this reading.

Through the dichroscope

Star Diopside One colour (no pleochroism) IDENTICAL AT EVERY ANGLE Star Diopside shows no pleochroism, so both windows match at every orientation — turning the instrument changes nothing. That is a real negative result, and the reason it is worth knowing is below. Computed from pleochroism and pleochroic colours in gems.json. Window tints are derived mechanically from the colour words, not chosen; a neutral pair depicts no colour at all.

Drawn from the pleochroism above. Two windows that match mean either no pleochroism or the wrong angle — turn the instrument to tell. How the dichroscope compares.

Key Differentiators

Common Simulants

Commonly Confused With

Commonly confused with: Star Ruby, Star Sapphire.

Measurement Guides

Identifying a star diopside? Loupewise walks through these tests in order — RI, SG, fluorescence, and more.

Try Loupewise Free →

Studying for the GIA, FGA, or FEEG practical? Star Diopside is one of the 132 species in Loupewise’s drill and exam pool — practice identifying it from its measured properties under timed exam conditions.

Practice exams →